ZW3D CAD Tips (Configuration ——What to do after an Emergency Backup occurs)

\You should execute Tools > Fix Objects at the Object Level after restarting ZW3D with session data saved by the Emergency backup feature located on the General Tab of the ZW3D Configuration Form.  This will clear temporary display data associated with parts and sketches.

 

Emergency session backup is not guaranteed to contain good data.It depends on the nature of the crash and how much control is given to ZW3D during it. If a user tries to recover data from an emergency session backup, he should try to verify it before archiving it for future use. That can be done by regening parts, regening drawing views, regening CAM toolpaths, etc. An unarchived emergency session backup could reference data from ZW3D files external to the session. If any of those files are modified between the time that the original session started and the time that the user tries to recover an emergency backup referencing the files, database corruption is nearly guaranteed.


© 2013 ZWCAD Software Co., Ltd. All rights reserved.
All trademarks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.